Autoclaves Sterilizer

MM-AUT001 Autoclave 230L

Product Description

Standard Features :

  • Secure Touch – Touch Screen Controller
  • Front loading compact autoclave
  • 230 liters
  • 5 Programs
  • Virtual Printer
  • New Swift lock rapid access safety closure
  • Over temperature water cut out
  • Thermocouple entry port
  • Low Water Alarm on Internal Water Tank
  • Automatic timed air purge system
  • Pressure gauge
  • Vent valve
  • Stainless Steel Pressure Vessel.
  • Safety Testing
  • On Screen Graph display
  • Heaters in chamber
  • Printer (optional)


Specification


Overall Capacity Chamber Diameter Working Depth Overall Dimensions Operating Range
230 Litres 600mm 735mm 900x1357x1590 mm (wxdxh) 100 -138oC (0.2-2.4 bar)
Power Requirements 3 phase + 20 Amps, 12kW.      
Steam & Drainage Requirements Water ?? 15mm bsp; 2-6 Bar 4L/min, Drainage: 35mm, ideally without manifold, to withstand free flowing steam      
Approx. Nett Weight: Shipping Weight Shipping Dimensions    
465kg 500kg 107x170x182cm (wxdxh)    


Control system:

    • Touch screen version of the Tried and Tested "Secure2" controller
    • Audible warnings End of Cycle, Water Level, Faults etc
    • Easy Fingertip Operation even when wearing Lab Gloves
    • Selectable security operating levels with access PIN codes
    • Built-in provision for mandatory Safety valve tests etc
    • Internal and External plus 2 - colour printer options
    • Easy selection of program by Name and Settings
    • Onscreen chart graph display of running cycle
    • Easy Muting for audible Cycle warnings
    • Audible confirmation of key presses
    • Continuous Onscreen Display of Program Info, Times, Temperatures, Pressure, Cycle stage, Cycle Counter etc
    • New "Virtual Printer" Stores cycle details (1-2 months typical usage stored) in Printout format for easy download to PC laptop or external printer
    • Internal Fault Detection with automatic fault diagnosis and 3 fault memories for easy servicing
    • Simple to use Controls set out on the large 5.7" illuminated display with menus for all operations
    • Optional Communications including Ethernet, and USB connections


Safety Features:

    • Cooling locks: (in accordance with H.S.E. PM73) preventing opening of autoclave above 80ºC. (for fluid & discard cycles
    • Audible & Visual Alarms: for Cycle Fault - Cycle Interruption - Sterilize
    • Failure - Water Low - Door Unlocked
    • Door Seal: Self Energising / Service independent
    • Door: The door release is interlocked by both temperature and pressure to ensure all residual pressure has completely and effectively vented to atmosphere before the doors can be opened. The door will retain its positions in the event of failure of any service. The door is thermally insulated to prevent the surface temperature presenting a hazard to operators. The surface temperature will not exceed IEC 61010 requirements. A cycle cannot start until the door is closed and locked. Steam cannot be applied to the chamber unless the door is closed and locked.
    • Interlocks: Safety interlocks are provided, and are achieved by hardware, separate from and additional to the control system. All interlocks are configured to fail-safe and to provide a signal to the control system to indicate that normal operation has been prevented, and to terminate the current cycle. The interlock system is designed so that its function can be tested during routine maintenance. Safety related interlocks are either hard wired or piped. The following safety interlocks are provided: If the door is not closed, the steam supply to the chamber will be isolated If the pressure in the chamber exceeds 0.15 bar the door will remain locked.